During
the earliest day, the alternating current is mainly used for resistive load
such as electric lamp and electric heater. That electrical load is resistive
type whereby the use of single-phase system works well. However, when ac motor
is developed, the single-phase system may not function well since the ac motor
require higher starting torque for self-starting.
So
what did they do? In order to make the ac motor to self-start, it is fitted with
auxiliary winding but the problem is, there will always an alternating
component with frequency that is double the frequency of power supply. This
scenario is okay for small motor but it will cause a noisy and vibration during
operation for a large motor.
Single-phase
voltage source are originated from three-phase system. In a balance three-phase
system, there are three sinusoidal voltage sources of equal amplitude and equal
frequency of variation but out of phase with each other by 2π/3 or 120° but for
single-phase system is only having one.
An
important advantage of three-phase power supply is that three-phase motors have
a non-zero starting torque as compared with the single-phase system.
The
characteristic of three-phase system is the currents and voltages are balanced everywhere
in the circuit. The most important property of such a circuit is that though
the power in an individual phase is pulsating and varies at twice the supply
frequency, the sum of powers delivered by all the phases is constant at every
instant of time.